Steiel Multi-Parametric Control Unit MC14 Ph/T7

Valuation Valuation Valuation Valuation Valuation 5/5
Steiel Multi-Parametric Control Unit MC14 Ph/T7
Final Price 3.190,00 €
Reference: 23835

DELIVERY 3/7 DAYS

WORK DAYS

/
Factory order
Expected warehouse departure date: 26/12/2024 - 27/12/2024
Add to favorites
2-line LCD display, configurable digital and analogue outputs, and a serial port for connection to a PC or remote management system. The measurement inputs can be configured at the factory according to customer requirements.
Panel MC14 pH / T 7 CLE (open amperometric cell) without pumps with Modbus
Basic information on data protection. - In accordance with the GDPR and loPDGDD, JARPIS SL will process the data provided, in order to publish your comment, control that it is not offensive, discriminatory, incite hatred and violence or disseminate personal data, and, where appropriate, proceed to its deletion in accordance with current legal regulations and provided that you authorize us in advance, we will send information related to our activity and / or newsletter. You may exercise, if you wish, the rights of access, rectification, deletion, and others recognized in the aforementioned regulations. To learn more about how we are processing your data, please access our privacy policy.

Multilingual interface

Inputs for 5 measurements (4 to be specified when ordering temperature); in case of double input for CAC six.

Digital outputs: configurable relays, setting thresholds, alarms (maximum/minimum), proportional time (PWM) or pulse (PFM) regulation, timed settings Possibility of having a low voltage output (24V~), for the control of small dosing pumps or solenoid valves without the addition of other transformers and with safety voltage.

Analogue outputs for exporting measured values to external devices; galvanically isolated.

OFF input for switching off the setpoint relays (to be connected to an external contact, e.g. filter pump switch)

FLOW input for controlling the water flow to the device

IMP input for freezing the measurement when the system is stopped or synchro- nisation with automatic flushing

OK output for remote signalling of the correct operation of the device Alarms and errors (diagnostics) displayed directly on the screen

Date and time always present on the display, even without power supply Programming / calibration data storage in memory 10 years Data logging downloadable via serial port (internal datalogger)

RS232C or RS485 serial output (specify when ordering), with galvanic isolation; compatible with our standard (ASCII without protocol) or with Modbus RTU protocol